TABLES 1 TABLE 1-A INSPECTION LEVEL - General Level II SAMPLING PLAN - Single Normal Sample Sizes and Reject Levels Acceptable Quality Level (AQL) Lot Code Sample .65 1.0 1.5 2.5 4.0 6.5 10 15 Size Letter Size (Re) (Re) (Re) (Re) (Re) (Re) (Re) (Re) 2 to 8 A 2 || || || || \/ 1 /\ \/ || || || || || 9 to 15 B 3 || || || \/ 1 /\ \/ 2 || || || || 16 to 25 C 5 || || \/ 1 /\ \/ 2 3 || || || 26 to 50 D 8 || \/ 1 /\ \/ 2 3 4 || || 51 to 90 E 13 \/ 1 /\ \/ 2 3 4 6 || 91 to 150 F 20 1 /\ \/ 2 3 4 6 8 || 151 to 280 G 32 /\ \/ 2 3 4 6 8 11 || 281 to 500 H 50 \/ 2 3 4 6 8 11 15 501 to 1,200 J 80 2 3 4 6 8 11 15 22 1,201 to 3,200 K 125 3 4 6 8 11 15 22 /\ || 3,201 to 10,000 L 200 4 6 8 11 15 22 /\ || || || 10,001 to 35,000 M 315 6 8 11 15 22 /\ || || || || || 35,001 to 150,000 N 500 8 11 15 22 /\ || || || || || || || 150.001 to 500,000 P 800 11 15 22 /\ || || || || || || || || || 500,001 to over Q 1250 15 22 /\ || || || || || NOTE TO WRITER: TABLE 1-A above is developed from MIL-STD-105E using 2 TABLE I Sample size code letters and TABLE II-A for single sampling plans. * When sample sizes equal, or exceed the population, or lot sizes, the QAE should consider a different surveillance method. \/ = use first sampling plan below arrow /\ = use first sampling plan above arrow E-24 TABLE 1-B INSPECTION LEVEL - General Level III SAMPLING PLAN - Single Tightened Sampling Sizes and Reject Levels Acceptable Quality Level (AQL) Lot Code Sample .65 1.0 1.5 2.5 4.0 6.5 10 15 Size Letter Size (Re) (Re) (Re) (Re) (Re) (Re) (Re) (Re) 2 to 8 A 2 || || || || || \/ || || || || || || || || || 9 to 15 B 3 || || || || \/ 1 || \/ || || || || || 16 to 25 C 5 || || || \/ 1 || \/ 2 || || || || 26 to 50 D 8 || || \/ 1 || \/ 2 3 || || || 51 to 90 E 13 || \/ 1 || \/ 2 3 4 || || 91 to 150 F 20 \/ 1 || \/ 2 3 4 6 || 51 to 280 G 32 1 || \/ 2 3 4 6 9 || 281 to 500 H 50 || \/ 2 3 4 6 9 13 || 501 to 1,200 J 80 \/ 2 3 4 6 9 13 19 1,201 to 3,200 K 125 2 3 4 6 9 13 19 /\ || 3,201 to 10,000 L 200 3 4 6 9 13 19 /\ || || || 10,001 to 35,000 M 315 4 6 9 13 19 /\ || || || || || 3 35,001 to 150,000 N 500 6 9 13 19 /\ || || || || || || || 150,001 to 500,000 P 800 9 13 19 /\ || || || || || || || || || 500,001 to over Q 1250 13 19 /\ || || || || || NOTE TO WRITER: Table 1-B above, is developed from MIL-STD 105E using TABLE I Sample size code letters, and TABLE II-B for single sampling plans. * When sample sizes equal, or exceed the population, or lot sizes, the QAE should consider a different surveillance method. \/ = use first sampling plan below arrow /\ = use first sampling plan above arrow E-25 TABLE 1-C INSPECTION LEVEL - General Level I SAMPLING PLAN - Single Reduced Sampling Sizes and Reject Levels Acceptable Quality Level (AQL) Lot Code Sample .65 1.0 1.5 2.5 4.0 6.5 10 15 Size Letter Size (Re) (Re) (Re) (Re) (Re) (Re) (Re) (Re) 2 to 8 A 2 || || || || \/ 1 || \/ || || || || || 9 to 15 B 2 || || || \/ 1 /\ \/ 2 || || || || 16 to 25 C 2 || || \/ 1 /\ \/ 2 3 || || || 26 to 50 D 3 || \/ 1 /\ \/ 2 3 4 || || 51 to 90 E 5 \/ 1 /\ \/ 2 3 4 5 || 91 to 150 F 8 1 /\ \/ 2 3 4 5 6 || 151 to 280 G 13 /\ \/ 2 3 4 5 6 8 || 281 to 500 H 20 \/ 2 3 4 5 6 8 10 4 501 to 1,200 J 32 2 3 4 5 6 8 10 13 1,201 to 3,200 K 50 3 4 5 6 8 10 13 /\ || 3,201 to 10,000 L 80 4 5 6 8 10 13 /\ || || || 10,001 to 35,000 M 125 5 6 8 10 13 /\ || || || || || 35,001 to 150,000 N 200 6 8 10 13 /\ || || || || || || || 150,001 to 500,000 P 315 8 10 13 /\ || || || || || || || || || 500,001 to over Q 500 10 13 /\ || || || || || NOTE TO WRITER: TABLE 1-C above, is developed from MIL-STD-105E using TABLE I Sample size code letters, and TABLE II-C for single sampling plans. * When sample sizes equal, or exceed the population, or lot sizes, the QAE should consider a different surveillance method. \/ = use first sampling plan below arrow /\ = use first sampling plan above arrow E-26 5